Used Spex Geno/Grinder 2000 for sale by New Life ...

Spex CertiPrep 2000 Geno/Grinder Sample Prep Shaker Tissue Homogenizer. At a Glance. -Application: Sample Preparation / Homogenization. -Functional Condition. -500-2000 Strokes per Minute. -Capacity: (2) Well Plate Holders. Condition. This product is in fair cosmetic condition and includes two plate holders. The product has been tested by NLS ...

E.Z.N.A.® Universal Pathogen Kit

2019-1-9 · For best results, a Mixer Mill, such as Spex CertiPrep Geno/Grinder® 2010 or Qiagen Tissuelyser, should be used. Note: Depending on the sample type and amount, the volume of SLX-Mlus Buffer may need to be adjusted so that 300 µL can be recovered during Step 12. 5. Centrifuge at 1,000-2,000 x g for 15 seconds at room temperature.

Evaluation of X‐Ray Fluorescence Spectroscopy as a Tool ...

2019-11-1 · Pea seeds were ground using a Geno Grinder 10 (SPEX SamplePrep). Three circular discs, referred to as "pellets," per sample were prepared using a 13-mm stainless steel pellet die in a hydraulic pellet press (PIKE Technologies, Auto-CrushIR) by applying pressure for 42 s (1 t for 4 s, 0 t for 30 s, 3.5 t for 4 s, and 7 t for 4 s) at the ...

Mag-Bind® Stool DNA 96 Kit

2021-7-9 · best results, a Mixer Mill, such as Spex CertiPrep Geno/Grinder® 2010 or Omni International''s Bead Ruptor 96, should be used. Note: Depending on the sample amount and type, the amount of SLX-Mlus Buffer may need to be adjusted so that 300 µL can be recovered after Step 9. Mag-Bind® Stool DNA 96 Kit - Inhibitor Rich Protocol

Automatic Electric Fluxers. Envirotech Online

2000-1-1 · Katanax Electric Fluxers are now available through SPEX CertiPrep Ltd for sale in Europe. These automated fusion machines are tied to a simple, yet high-performance, electric furnace while meeting the demands of both small and large sample preparation applications.

Amplify Your PCR Success from Cole-Parmer

The Geno/Grinder was tested to determine if this technology could be used to lyse bacterial cells. Standard 96-well titer plates were used with 400 to 600 μl silica grinding beads (Molecular Biology Grade, . no. 2166).The delivery of the beads into each cell of the titer plate can be accomplished in a number of ways.

genogrinder grinding ball

Genogrinder at Thomas Scientific Genogrinder found in: Racks, Clamps and Holders for the 2000 Geno/Grinder, 2010 Geno/Grinder®, Lrg Cap Clamp Assbly - 2000 Geno/Grinder, Grinding Beads for.. Cannabis Testing - SPEX CertiPrep

DNA Purification | DNA Extraction Methods | Promega

VA1920) but also a device capable of breaking up seed or leaf material (e.g., Geno/Grinder® 2000 from SPEX CertiPrep, Inc.). The yield depends on the source material and how well the seeds or leaf disks are pulverized prior to the genomic DNA isolation. Yield may range from 10–100ng from a single 8mm leaf punch.

Grinding and THE ULTIMATE PLANT & ANIMAL TISSUE …

2017-4-18 · The 2010 Geno/Grinder ... Best of all, our Demo Program is COMPLIMENTARY!!! Once you try our quality products you''ll ask y ourself howyou ever lived w hout them. ... SPEX CertiPrep Ltd 2 Dalston Gardens Stanmore, HA7 1BQ, UK Tel: +44 (0)20 8204 6656 Fax: +44 (0)20 8204 6654

Mag-Bind® Stool DNA 96 Kit

2016-11-16 · 4. Vortex at maximum speed for 3-5 minutes to lyse and homogenize samples. For best results, a Mixer Mill, such as Spex CertiPrep Geno/Grinder® 2010 or Qiagen Tissuelyser, should be used. Note: Depending on the sample amount and type, the amount of SLX-Mlus Buffer may need to be adjusted so that 200 µL can be recovered after Step 4. 5.

Sonication

A.C. Taylor, in Advances in Structural Adhesive Bonding, 2010 7.3.3 Sonication. Sonication uses an ultrasonic bath or probe to apply sound energy to a liquid containing particles. Many authors combine sonication and mixing, especially when using probe sonicators, as the power is directed into a small volume and the low shear forces do not generally ensure that all the polymer …

Grasses use an alternatively wired bHLH transcription ...

2016-7-19 · Tissue was harvested, snap-frozen in liquid nitrogen, and ground using glass beads and a SPEX CertiPrep Geno Grinder 2000. DNA was extracted from a newly emerged leaf or from part of a young leaf using a hexadecyltrimethylammonium bromide (CTAB) DNA extraction protocol or using the DNeasy Plant Mini Kit (Qiagen) following the manufacturer''s ...

(PDF) WHIRLY1 is a major organizer of chloroplast nucleoids

2014-9-4 · state in a Geno Grinder (Type 2000, SPEX, CertiPrep, Munich, Germany) with 0.5 ml 80% (v/v) acetone buffered with 20 mM. T r i s,p H7. 8.A f t e rc e n t r i f u g a t i o n,t h ep e l l e tw a se ...

SPEX SamplePrep, LLC | SelectScience

SPEX SamplePrep, LLC was founded in 1954 to provide superior sample preparation equipment and supplies for spectroscopists. SPEX SamplePrep equipment is used to prepare samples for a wide range of analytical technologies including XRF, AA, and ICP. Much of our sample preparation equipment is also used for cutting-edge research in ...

Effect of Lysis Time and Other Variables on DNA …

2014-1-23 · The best conditions for processing fresh basil were found to be 90 sec. at 2000 cyc/min with the 2000 Geno/Grinder. Increasing the processing time to 120 sec. did not appear to offer any benefit. In addition, use of the Geno/Grinder gave higher quality DNA than was obtained using the competitive lyser.

Sample Preparation and Reference Materials for Scientists ...

2012-10-19 · Their Sample Preparation Division has a full range of laboratory mills including the Geno/Grinder – a unique shaker mill that aids in sample preparation for the QuEChERS method of pesticide residue analysis. They also offer laboratory presses, electric fusion fluxers and XRF accessories. Visit Spex CertiPrep on WWEM Stand 55.

Instant reaction: Seahawks blow out terrible Jaguars ...

2021-10-31 · Instant reaction: Seahawks blow out terrible Jaguars. The Jacksonville Jaguars played this game like they''d all been on one of Urban Meyer''s ''special'' nights out on Saturday. ''Dreadful'' hardly feels like a strong enough word to describe them. It''s Hallowe''en, not Christmas. Yet this was a gift for the Seahawks.

Mixing and Blending the Cool ideas keep Coming…

2017-4-18 · Geno/Grinder® consistently produced higher recovery rates by an average of over 18%. 2 – Improved cell lysis and DNA yields from plant tissue A study was performed to discover what Geno/Grinder® processing variables significantly increased or decreased the yields of genomic DNA in fresh basil. Variables investigated included homogenization

SPEX 2010-115

Spex SamplePrep® Geno/Grinder® Automated Tissue Homogenizer and Cell Lyser The Geno/Grinder® is an automated high-throughput plant & animal tissue homogenizer and cell lyser. It is equipped with an adjustable clamp that accommodates a full range of sample vials from 2mL to 50mL centrifuge tubes or up to six deep-well titer plates.

Subaru EE20 Diesel Engine

Subaru''s EE20 engine was a 2.0-litre horizontally-opposed (or ''boxer'') four-cylinder turbo-diesel engine. For Australia, the EE20 diesel engine was first offered in the Subaru BR Outback in 2009 and subsequently powered the Subaru SH Forester, SJ Forester and BS Outback.The EE20 diesel engine underwent substantial changes in 2014 to comply with Euro 6 emissions …

SEPX SamplePrep® Adjustable Clamp for Original 2010 …

Adjustable Clamp. It holds up to three layers of deep-well titer plates and other titer plates, tubes and vials of equal or lesser height. The clamp has a hand-knob with a quick-release button to move it up or down a central threaded rod. The 2189G Adjust

sat spex geno 2020 grinder

Wolf special offer - Ball mill Spex Certiprep Geno / Grinder grinding ball type, 450W motor, for 0.6 to 800ml sample volumes, maximum speed 1,750rpm, grinding ball set not included. Price includes clamp and nesting trays but accessories may be required depending on your application.

Ultra-fast proteomics with Scanning SWATH | Nature ...

2021-3-25 · The best results in terms of identification and quantitative precision were achieved with a window size of 10 m/z (Supplementary Fig. 2a). Reducing the window size further would have resulted in ...

Geno/Grinder 2010-230

The use of 96-well micro titer plates and deep well plates in the Geno/Grinder® has been shown to give reproducible homogenization yields for all samples and is well suited for cell disruption of muscle and internal organs such as liver. large Clamp assembly SPEX SamplePrep 15 Liberty Steet Metuchen, NJ 08840-9978 Tel: 732.623.0465 Fax: 732 ...

SPEX CertiPrep Ltd Announces the Next Generation 2010 …

2010-3-10 · This completely remodeled product is based on the well established 2000 Geno/Grinder®. It employs a unique design for vigorous ''true'' up-and-down motion. The Geno/Grinder® is capable of processing up to four deep-well titer plates and sample vials from 0.6 to 50mL using one easy to use assembly.

DNA / RNA RESEARCH CROP SCIENCE

2021-3-2 · Geno/Grinder.® Our Cryo-Blocks are designed to be chilled in the 2600 Cryo-Station. Vials or titer plates containing temperature-sensitive samples are placed in the Cryo-Blocks and then put directly into the Geno/Grinder®. Tissue samples can be maintained at subzero temperatures during grinding to increase yields.

Identification by means of molecular tools of the ...

Briefly, 5 g of the central area of cheese were weighed and 20 g of 10% (w/v) TCA were added. Samples were homogenized for 5 min in a vertical Geno/Grinder® 2010 230 SPEX homogenizer at 800 rpm and centrifuged at 4,824 g for 10 min. The supernatants were filtered through Whatman No. 1 filters. For the derivatization process, 200 μL of ...

Frontiers | Best practices for evaluating single ...

Best practices for evaluating single nucleotide variant calling methods for microbial genomics Nathan D. Olson 1 *, Steven P. Lund 2, Rebecca E. Colman 3, Jeffrey T. Foster 4 †, Jason W. Sahl 3, 4, James M. Schupp 3, Paul Keim 3, 4, Jayne B. Morrow 1, Marc L. Salit 1, 5 and Justin M. Zook 1

Geno/Grinder 2010, 115V/60Hz, CE Approved

LY320135. Rimonabant Hydrochloride. CB1 Antibodies. Anti-Cannabinoid receptor 1 antibody/goat. Anti-Cannabinoid Receptor 1 Antibody/Rabbit. ANTI-CB1. Anti-CNR1 Antibody. Monoclonal Anti-CNR1 Antibody. CB1/CB2 Agonists.